Especificação LR8000
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 4 | 
|---|---|
| Probe length L [mm] | 100…1600 | 
| Process connection | threaded connection G 3/4 external thread | 
Application
| System | gold-plated contacts | 
|---|---|
| Application | for industrial applications | 
| Media | Liquids | 
| Dielectric constant of the medium | ≥ 1,8; (for media with a dielectric constant of 1.8…5 (e.g. oils), a coaxial pipe is needed for operation) | 
| Recommended media | water; water-based media; oils; oil-based media | 
| Cannot be used for | See the operating instructions, chapter “Function and features”. | 
| Process temperature [°C] | -25…80; (90 < 1 h ; see note under remarks) | 
| Pressure rating [bar] | 16 | 
| Vacuum resistance [mbar] | -1000 | 
| MAWP (for applications according to CRN) [bar] | 16 | 
Electrical data
| Operating voltage [V] | 18…30 DC | 
|---|---|
| Current consumption [mA] | < 30 | 
| Protection class | III | 
| Reverse polarity protection | yes | 
| Power-on delay time [s] | < 3 | 
| Measuring principle | guided wave radar | 
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 4 | 
|---|
Outputs
| Total number of outputs | 4 | 
|---|---|
| Output signal | switching signal; IO-Link | 
| Electrical design | PNP | 
| Number of digital outputs | 4 | 
| Output function | normally open / closed; (configurable) | 
| Max. voltage drop switching output DC [V] | 2.5 | 
| Permanent current rating of switching output DC [mA] | 200 | 
| Short-circuit protection | yes | 
| Type of short-circuit protection | thermal, pulsed | 
| Overload protection | yes | 
Measuring/setting range
| Probe length L [mm] | 100…1600 | 
|---|---|
| Active range A [mm] | L-40; (when set to oil and oil based media: L-60) | 
| Inactive range I1 / I2 [mm] | 30 / 10; (when set to oil and oil based media: 30 / 30) | 
| Sampling rate [Hz] | 4 | 
Setting range
| Set point SP [mm] | 15…L-30 | |
|---|---|---|
| Note on setpoint SP | 
 | |
| Reset point rP [mm] | 10… L-35 | |
| Note on reset point rP | 
 | |
| In steps of [mm] | 5 | |
| Hysteresis [mm] | > 5 | 
Accuracy / deviations
| Repeatability [mm] | ± 5 | 
|---|---|
| Measuring error [mm] | ± 7 | 
| Offset error [mm] | 5 | 
| Resolution [mm] | 1 | 
| Temperature drift per 10 K | ± 0.2 % | 
Interfaces
| Communication interface | IO-Link | ||||
|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 CDV | ||||
| Profiles | no profile | ||||
| SIO mode | yes | ||||
| Required master port class | A | ||||
| Process data analog | 1 | ||||
| Process data binary | 4 | ||||
| Min. process cycle time [ms] | 2.3 | ||||
| Supported DeviceIDs | 
 | 
Operating conditions
| Ambient temperature [°C] | -25…60 | 
|---|---|
| Storage temperature [°C] | -40…85 | 
| Protection | IP 67 | 
Tests / approvals
| EMC | 
 | ||||||
|---|---|---|---|---|---|---|---|
| Shock resistance | 
 | ||||||
| Vibration resistance | 
 | ||||||
| MTTF [years] | 205 | ||||||
| UL approval | 
 | 
Mechanical data
| Weight [g] | 380.45 | 
|---|---|
| Material | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V | 
| Materials (wetted parts) | stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; sealing: NBR fiber-reinforced | 
| Process connection | threaded connection G 3/4 external thread | 
Displays / operating elements
| Display | 
 | 
|---|
Remarks



 
				 
				 
				 
				 
				 
				 
				 
				
Avaliações